MODEL CIB-L PUMP INERTIA BASE

KINETICS® Model CIB-L Pump Inertia Base is a reinforced concrete-filled inertia base frame designed to support pumps and mechanical equipment requiring vibration isolation, anchorage, and motion control. Engineered for MEP, HVAC, and mechanical plant applications across the UAE, GCC, and MENA region.

Product Details

Kinetics Noise Control Inc. Products

Product Description

KINETICS® CIB-L inertia base frames are specifically designed and engineered to receive poured concrete for use in supporting mechanical equipment that requires a reinforced concrete inertia base. When filled with concrete and supported by suitable KINETICS® vibration isolators, the Model CIB-L provides effective equipment isolation, structural support, anchorage, and vibration amplitude control for pumps, chillers, compressors, fans, and other rotating or reciprocating equipment.

The CIB-L Pump Inertia Base uses an integrated structural design that combines perimeter steel channels, isolator support brackets, reinforcing rods, anchor bolts, and concrete fill into a controlled load transfer system. This design uses steel in tension and concrete in compression to achieve high strength and stiffness while minimizing steel frame weight. Completed inertia bases using Model CIB-L frames are stronger and stiffer than standard inertia base frames using heavier steel members.

Standard KINETICS® CIB-L inertia base frames are available in 6 in. (152 mm), 8 in. (203 mm), 10 in. (254 mm), and 12 in. (305 mm) thicknesses. Each frame includes integral isolator support brackets, a steel channel perimeter pouring frame, 1/2 in. (13 mm) diameter reinforcing rods on 8 in. (203 mm) centers each way, and steel anchor bolts prelocated and fixed in the correct positions. The frames are delivered to the job site completely welded and ready to be filled with concrete, helping reduce site labor, installation time, and overall installation cost.

Inertia bases are used to support mechanical equipment, reduce equipment vibration, provide attachment points for vibration isolators, prevent differential movement between driving and driven components, reduce rocking by lowering the equipment center of gravity, control movement during start-up and shut-down, reduce reaction movement from operating loads, and act as a noise barrier. The Model CIB-L is suitable for mechanical rooms, chiller plants, pump rooms, HVAC systems, industrial facilities, commercial towers, hospitals, hotels, infrastructure projects, and other MEP applications requiring dependable vibration control and equipment stability.

Installation support is available for CIB inertia base installation with FHS isolators and FDS isolators. Available product support documents include Datasheet PDF, Installation Guide, Technical Manual, CAD Drawings, and Test Reports.

CIB Inertia Base Installation with FHS Isolators

 

CIB Inertia Base Installation with FDS Isolators

Application

  • Close-coupled and base-mounted pumps in HVAC and MEP systems
  • Open-type centrifugal chillers and chiller plant equipment
  • Reciprocating air and refrigeration compressors
  • Heat pumps and mechanical plant equipment
  • Centrifugal fans requiring vibration isolation support
  • Internal combustion engines and similar dynamic equipment
  • Mechanical rooms, pump rooms, chiller rooms, and plant areas
  • Commercial, industrial, healthcare, hospitality, data center, and infrastructure projects
  • Equipment installations requiring concrete inertia bases with vibration isolators
  • CIB inertia base installations with FHS or FDS isolators

Features & Benefits

  • Designed to receive poured concrete for reinforced inertia base construction
  • Provides equipment support, anchorage, vibration isolation, and amplitude control
  • Integrated perimeter channels, isolator support brackets, reinforcing rods, and anchor bolts
  • Controlled load transfer system using steel in tension and concrete in compression
  • Stronger and stiffer completed base compared with standard heavier steel frame designs
  • Standard thickness options: 6 in. (152 mm), 8 in. (203 mm), 10 in. (254 mm), and 12 in. (305 mm)
  • Includes 1/2 in. (13 mm) diameter reinforcing rods on 8 in. (203 mm) centers each way
  • Steel anchor bolts are prelocated and fixed in proper locations
  • Delivered completely welded and ready for concrete filling on site
  • Helps minimize job-site labor and installation time
  • Reduces equipment vibration, rocking, reaction movement, and start-up/shut-down motion
  • Supports improved equipment stability, mechanical performance, and acoustic control
  • Suitable for consultants, contractors, MEP engineers, and project developers across UAE, GCC, Middle East, and MENA projects

Installation Guidelines

Click below to view the complete installation guidelines.

Installation Guidelines

Available Downloads Options

Datasheet
PDF
Installation Guide
Technical Manual
CAD
Drawings
Test
Reports