Fabricated, made-to-spec housings permit flexible isolation system design for a range of slab thicknesses, air cavities, and applied loads. Your acoustical design team can assist you with your specific requirements.
Required deflection and corresponding natural frequency for the floor isolators can be determined using one inch (1″) or two inch (2”) rated coil springs. Ask us about options for the airspace between the isolated (lifted) slab and the structural slab.
Proven effective for intense impact applications ranging from floors for sensitive lab measuring equipment (e.g. metrology and surgical labs) to sports floors over retail/commercial spaces.
Spring isolators natural frequencies (fn) of 3.13 Hz for 1″ rated deflection springs and 2.21 Hz for 2″ rated deflection spring. Other rated deflection springs are available.
Factory-engineered shop drawings detail consider spacing, spring load/deflections and structural floor flatness requirements.
Rubber cap assembly protects against resonant frequencies.
In-slab or perimeter seismic restraint elements available where required.
Springs ship in ready-to-install sub-assemblies.
Castings are stocked ready to ship.