Chiller Stacks and Pergolas

KINETICS® NOISEBLOCK™ Chiller Stacks and Pergolas are acoustic noise-control systems designed to reduce upward sound propagation from up-blast chiller fans while maintaining low airflow resistance for rooftop HVAC and chiller plant projects across the UAE, GCC, Middle East, and MENA region.

Product Details

Kinetics Noise Control Inc. Products

Product Description

Acoustic Control for Up-Blast Chiller Fans
KINETICS® NOISEBLOCK™ Chiller Stacks and Pergolas are engineered noise-control solutions for air-cooled chillers where fan noise is projected upward from rooftop or outdoor mechanical equipment. The system is designed to control upward sound propagation from up-blast chiller fans, helping reduce noise impact on nearby buildings, upper floors, surrounding properties, and sensitive project boundaries.

Designed for Low Pressure Drop
Chiller noise-control systems must be carefully designed so that acoustic treatment does not restrict chiller airflow or affect HVAC performance. NOISEBLOCK™ Chiller Stacks and Pergolas are designed to provide an estimated 12–15 dBA reduction at 5′-0″ above while exhibiting no more than 0.05 inches WG pressure drop at the rated chiller airflow CFM.

Independent Support for Rooftop HVAC Coordination
The chiller stack is designed to be supported completely separate from the chiller, helping protect the equipment from unnecessary structural loading. The support structure is supplied as a completely bolt-together system with no field welding required, and all bolts, nuts, and washers are included for installation coordination.

Ideal for UAE, GCC, and MENA Chiller Noise-Control Projects
For consultants, MEP contractors, acoustic consultants, and developers, NOISEBLOCK™ Chiller Stacks and Pergolas provide a practical solution for rooftop chillers, mechanical plant decks, commercial towers, hospitals, hotels, schools, data centers, district cooling facilities, and infrastructure projects where chiller fan noise must be addressed without compromising system airflow.

Application

  • Rooftop air-cooled chiller noise control
  • Up-blast chiller fan acoustic treatment
  • Mechanical plant deck noise mitigation
  • HVAC chiller yard acoustic control
  • Commercial building and high-rise rooftop chiller installations
  • Hospitals, hotels, schools, data centers, and mixed-use developments
  • District cooling and utility plant noise-control projects
  • Property line and nearby receiver noise reduction for MEP equipment

Features & Benefits

  • Controls upward sound propagation from up-blast chiller fans
  • Estimated 12–15 dBA noise reduction at 5′-0″ above
  • Designed for no more than 0.05 inches WG pressure drop at rated chiller airflow CFM
  • Helps maintain chiller airflow and HVAC equipment operation
  • Stack support is completely independent of the chiller
  • Bolt-together support structure with no field welding required
  • Supplied with required bolts, nuts, and washers
  • Suitable for rooftop, outdoor, and mechanical plant applications
  • Helps reduce chiller fan noise impact on surrounding buildings and sensitive areas
  • Supports acoustic design coordination for UAE, GCC, Middle East, and MENA projects