Kinetics Model KIP-SP Scored Fiberglass Isolation Pads are modular industrial vibration isolators designed to reduce the transmission of noise, shock and high-frequency vibration from machinery into the supporting structure. Manufactured from precompressed molded fiberglass with a flexible moisture-impervious elastomeric coating, KIP-SP pads are supplied as prescored sheets that can be separated into application-specific sizes for industrial projects across the UAE, GCC and MENA region.
Engineered for Performance.
Kinetics Group supplies KINETICS Model KIP-SP scored fiberglass vibration isolation pads for industrial machinery in the UAE, GCC and MENA region. The pads reduce transmitted noise, shock and high-frequency vibration using precompressed molded fiberglass coated with a flexible moisture-resistant elastomeric membrane. KIP-SP is supplied in 457 × 457 × 13 mm prescored sheets, with 50 × 50 mm modules, loading densities from 5 to 100 PSI and nominal deflections from 2 to 4 mm.
KINETICS® Model KIP-SP Scored Fiberglass Isolation Pads are modular industrial vibration isolators designed to reduce the transmission of noise, shock and high-frequency vibration between operating machinery and the supporting floor, foundation or structural system.
KIP-SP pads are manufactured from precompressed molded inorganic fiberglass. Each pad is individually coated with a flexible, moisture-impervious elastomeric membrane that protects the fiberglass while allowing the isolation medium to provide controlled motion damping.
The fiberglass consists of fine bonded and annealed glass fibres stabilized during manufacture. The natural frequency of the isolator remains essentially constant across a wide operating-load range, while stiffness increases proportionally as the applied load increases. This provides permanent and dynamically predictable support characteristics for correctly selected industrial machinery applications.
Model KIP-SP is supplied as a 457 × 457 × 13 mm prescored sheet. The sheet is scored at 50 mm centres in both directions, allowing installers to separate it into individual 50 × 50 × 13 mm modules or larger multiples according to the equipment load, mounting-foot dimensions and required bearing area.
Kinetics Group provides KIP-SP product-selection, technical-documentation and quotation support for consultants, contractors, machinery installers and industrial facilities across Dubai, Abu Dhabi, the UAE, GCC, Middle East and wider MENA region.
KIP-SP fiberglass vibration isolation pads are designed primarily for industrial process equipment and general-purpose machinery that generates noise, shock or high-frequency vibration.
Typical applications include:
KIP-SP should be selected according to the actual supported load, equipment-foot area, required deflection, operating characteristics and project vibration-isolation schedule.
| Property | Model KIP-SP |
|---|---|
| Product type | Prescored fiberglass vibration isolation pad |
| Standard sheet length | 18 inches / 457 mm |
| Standard sheet width | 18 inches / 457 mm |
| Standard thickness | 1/2 inch / 13 mm |
| Scoring centres | 2 inches / 50 mm each way |
| Smallest standard module | 2 × 2 × 1/2 inches |
| Metric module size | 50 × 50 × 13 mm |
| Loading-density range | 5 to 100 PSI |
| Metric loading-density range | Approximately 0.35 to 7 kg/cm² |
| Deflection range | 0.09 to 0.17 inch |
| Metric deflection range | Approximately 2 to 4 mm |
| Standard density types | KIP-SP-G, KIP-SP-L and KIP-SP-Q |
| Maximum glass-fibre diameter | 0.00027 inch / 6.8 microns |
| Fiberglass modulus of elasticity | 10.5 million PSI |
| Metric modulus stated in datasheet | 750,000 kg/cm² |
| Primary function | Noise, shock and high-frequency vibration isolation |
The number of modules required beneath each equipment foot must be calculated from the individual foot load and the allowable loading range of the selected KIP-SP density.
Do not select the pad area using total machine weight alone. Equipment weight may not be distributed equally between the mounting points, particularly where motors, drives, flywheels or other heavy components are positioned asymmetrically.
Provide the following information when requesting KIP-SP selection:
Use KIP-SP where a modular, prescored fiberglass sheet is required for industrial machinery producing noise, shock or high-frequency vibration.
Use standard KIP Fiberglass Isolation Pads where permanent, predictable fiberglass support is required in standard or specially configured pad arrangements.
Use AC Fiberglass Mounts where a contained, bolt-down fiberglass isolator with vertical lift control is required.
Use SN Special Non-Leveling Mounts for large punch presses and heavy industrial machinery where loading exceeds the capacity of standard machinery mounts and a custom steel load-transfer plate is required.
Final product selection must be based on the equipment load, speed, shock characteristics, required deflection, mounting configuration and supporting structure.
Technical literature and engineering documents are available through the Kinetics Group Downloads Centre.
Explore related vibration-control products and industrial solutions through Kinetics Group Industrial and Environmental Solutions.
The original manufacturer’s product reference is available from Kinetics Noise Control – KIP-SP Scored Fiberglass Isolators.
For product selection, technical submittals, availability and quotations, contact Kinetics Group.
KIP-SP pads are prescored industrial vibration isolators manufactured from precompressed molded fiberglass coated with a flexible moisture-impervious elastomeric membrane. They are used to reduce transmitted noise, shock and high-frequency vibration.
Each standard sheet measures 18 × 18 × 1/2 inches, equivalent to approximately 457 × 457 × 13 mm.
The sheet is scored at 2-inch or 50 mm centres in both directions. It can therefore be separated into individual 50 × 50 × 13 mm modules or larger multiples.
The KIP-SP range is available in fiberglass densities covering loading from 5 to 100 PSI, depending on the selected G, L or Q model and the total pad area.
The published deflection range is approximately 0.09 to 0.17 inch, or 2 to 4 mm, depending on the selected isolator density and applied loading.
Typical applications include conveyors, drills, dust collectors, motors, packaging machinery, printing presses, punch presses, stamping presses, textile machinery, woodworking equipment and other industrial machinery producing noise, shock or high-frequency vibration.
The sheets should be separated along the factory-scored 50 mm grid. The required number of modules must be calculated according to the actual load at each equipment mounting point.
KIP-SP is primarily intended for noise, shock and high-frequency vibration isolation. Machinery producing significant low-frequency vibration may require a spring isolator or another system selected according to the equipment speed and project criteria.
The selection is based on the actual load at each equipment foot divided by the allowable loading density of the selected KIP-SP model. Unequal machine-weight distribution must be considered.
Kinetics Group provides technical selection, documentation and quotation support for KIP-SP projects across the UAE, GCC, Middle East and MENA region.
KIP-SP fiberglass vibration isolation pads are designed primarily for industrial process equipment and general-purpose machinery that generates noise, shock or high-frequency vibration.
Typical applications include:
KIP-SP should be selected according to the actual supported load, equipment-foot area, required deflection, operating characteristics and project vibration-isolation schedule.
The supporting floor, plinth or foundation must be clean, level, structurally sound and capable of carrying the equipment load.
Place the selected KIP-SP pad area beneath each supported equipment foot or base location as shown on the approved selection or project drawing.
The full surface of each pad must be uniformly loaded. Avoid using small shims, narrow plates or concentrated contact points that load only part of the fiberglass pad.
Where levelling is required, use a full-size steel distribution plate or shim covering the complete selected pad area. The plate must distribute the load evenly without creating a concentrated edge load.
Cut or separate the sheet only along the factory-scored lines. Do not tear through the centre of an individual 50 × 50 mm module.
Maintain the selected number of modules beneath each mounting point. Removing modules after the product has been selected will increase the load per unit area and can change the isolation performance.
Anchor bolts, pipe connections, electrical conduits, guards and other rigid connections must not bypass or short-circuit the vibration isolation system.
Flexible connections may be required where rigid services connected to the machine could transmit vibration around the isolation pads.
Final installation must comply with the approved Kinetics selection, machinery requirements, consultant specifications and project drawings.