Case Studies

Kinetics Group

Our Latest Case Studies

Premium interiors should sound as refined as they look.

Six acoustically distinct spaces from the member lounge and ballroom to the gym and wellness studios, required room-specific reverberation control without visible panels or disruption to the interior design. Read how Kinetics used octave-band RT analysis from 125 Hz to 4,000 Hz and 740 m² of NRC 0.90 seamless acoustic plaster over 8/18Q perforated gypsum to provide 666 m² of equivalent absorption while coordinating lighting, ventilation, MEP and life-safety services.

Read the Full Case Study

Luxury living is defined not only by what residents see, but also by what they never have to hear.

With a 103 dBA exhaust fan discharging through a basement chiller ventilation shaft, this premium Dubai waterfront development required effective noise control without restricting airflow or compromising its architectural finish. Read how Kinetics combined octave-band acoustic analysis, a 600 mm double-bank acoustic louvre and 85 m² of absorptive wall lining to control breakout noise and protect the development’s acoustic comfort.

Read the Full Case Study

Behind every exceptional learning environment is an acoustic strategy that remains unseen, but never unheard.

From high-output generators and centralized chillers to rooftop HVAC equipment concealed behind architectural Mashrabiya screens, this project demanded a carefully engineered approach to noise control. Read how Kinetics combined predictive acoustic modelling, absorptive treatments and engineered barriers to deliver a quieter, more comfortable school environment.

Read the Full Case Study

wpChatIcon