KINETICS® Model ICW is a high-performance acoustic ceiling hanger designed to resiliently isolate suspended gypsum board ceilings from the supporting structure. The system incorporates a 1-inch rated deflection spring in series with a neoprene cup to reduce airborne sound, impact noise and low-frequency vibration transmission.
Model ICW is installed to joists or trusses and supports the isolated ceiling framing through a channel clip and levelling rod assembly. Its low-profile bracket design helps maximise available ceiling height while providing effective acoustic and vibration isolation.
Kinetics Group supplies KINETICS® ICW ceiling hangers for acoustic, architectural and specialist noise-control projects throughout the UAE, GCC and MENA region.
Engineered for Performance.
KINETICS® ICW is an acoustic spring ceiling hanger used to isolate suspended gypsum board ceilings from structural vibration and sound transmission. It combines a 1-inch deflection spring with a neoprene isolator to control airborne noise, impact noise and low-frequency vibration. Kinetics Group supplies ICW ceiling isolation systems for projects across the UAE, GCC and MENA region.
KINETICS® ICW is a high-performance acoustic spring ceiling hanger designed to resiliently isolate suspended gypsum board ceilings from the supporting building structure. The system uses a nominal 1-inch (25 mm) deflection spring in combination with a resilient neoprene element to help reduce airborne sound, impact noise and low-frequency structure-borne vibration.
ICW is specifically suited to ceiling systems supported from wood joists, engineered wood members and open-web trusses. Its side-mounted configuration allows the hanger to be installed directly to the supporting member while helping minimise the loss of available ceiling height.
Kinetics Group supplies KINETICS® ICW ceiling isolation systems for acoustic consultants, architects, contractors, developers and specialist acoustic projects throughout the UAE, GCC, Middle East and MENA region.
Conventional rigid ceiling connections can provide a direct transmission path for sound and vibration between the building structure and the occupied space below.
The ICW ceiling hanger introduces resilient spring isolation between the structural framing and the suspended gypsum ceiling. This mechanical separation helps reduce the transfer of vibration into the ceiling surface and improves the acoustic separation of the complete floor-ceiling assembly.
The full 1-inch spring deflection is particularly important for low-frequency isolation. Greater resilient deflection lowers the natural frequency of the suspended system, allowing the isolated ceiling to provide improved attenuation over a broad frequency range when correctly designed and installed.
For projects requiring specialist noise and vibration control solutions, ICW can form part of a complete engineered acoustic isolation strategy.
ICW is designed to improve isolation against two important forms of building noise:
Airborne noise includes speech, television, music and other sounds transmitted through the floor-ceiling construction.
Impact noise is generated by direct contact with the structure, including footsteps, dropped objects and movement on the floor above.
By resiliently decoupling the suspended gypsum ceiling from the supporting structure, ICW helps interrupt the transmission path through which this acoustic energy reaches the room below.
The hanger is especially valuable where control of low-frequency airborne and impact noise is required and where conventional resilient channels or shallow elastomeric isolation systems may not provide the required level of performance.
KINETICS® ICW incorporates coil springs selected to provide up to approximately 1 inch of nominal deflection at rated load.
Multiple spring capacities are available so the acoustic ceiling designer can match each hanger to the calculated load at its suspension point. Correct spring selection helps maintain consistent deflection, ceiling level and isolation performance across the entire suspended ceiling.
ICW spring selections include the following rated capacities:
| Model | Rated Capacity | Typical Operating Range |
|---|---|---|
| ICW-12 | 12 lb | 6–12 lb |
| ICW-18 | 18 lb | 9–18 lb |
| ICW-24 | 24 lb | 12–24 lb |
| ICW-30 | 30 lb | 15–30 lb |
| ICW-37 | 37 lb | 19–37 lb |
| ICW-50 | 50 lb | 25–50 lb |
| ICW-75 | 75 lb | 38–75 lb |
| ICW-100 | 100 lb | 50–100 lb |
| ICW-150 | 150 lb | 75–150 lb |
| ICW-210 | 210 lb | 105–210 lb |
Spring selection should be based on the actual calculated ceiling load supported by each hanger rather than applying one spring capacity throughout the entire installation.
Low-frequency sound is particularly difficult to control because structural building elements can readily transmit vibration over long distances.
The spring and neoprene combination used within the ICW hanger provides resilient isolation across a wide frequency range. Under the lightest typical loading conditions, the ICW system has a published maximum natural frequency of approximately 4.4 Hz.
This makes the system particularly relevant for applications requiring enhanced low-frequency isolation, including cinemas, screening rooms, home theatres, recording facilities, entertainment spaces and noise-sensitive residential environments.
Published testing demonstrates the high acoustic performance that can be achieved when ICW is incorporated into a correctly designed floor-ceiling assembly.
A tested construction using ICW hangers attached to 2 × 10 joists, together with fiberglass insulation and two layers of gypsum board, achieved ratings of:
STC 76 – Sound Transmission Class
IIC 62 – Impact Insulation Class
Published manufacturer data for different tested ICW assemblies reports an overall STC range of 57–76 and IIC range of 52–89, depending on the complete floor-ceiling construction.
These ratings apply to specific laboratory-tested assemblies and are not performance ratings for the hanger alone. Actual project results depend on the complete construction, including floor build-up, gypsum board mass, cavity insulation, structural framing, perimeter isolation, penetrations, flanking paths and installation workmanship.
ICW is engineered for applications where an isolated gypsum ceiling must be supported below structural wood framing.
Suitable supporting construction can include:
The hanger is secured to the side of the structural framing member, allowing the isolation spring and ceiling grid connection to remain compact.
This side-mounted configuration is particularly useful where the project requires high acoustic performance with minimal reduction in finished ceiling height.
The ICW hanger incorporates a channel clip and levelling assembly designed to support standard 1-1/2-inch cold-rolled steel carrying channel.
Drywall furring channels can then be installed as part of the specified suspended ceiling framing system before the required gypsum board layers are fixed.
The integrated levelling arrangement allows installers to adjust the elevation of the ceiling grid and achieve a flat finished ceiling while maintaining the specified spring loading.
This makes ICW a dedicated architectural acoustic ceiling isolation system rather than a general-purpose mechanical equipment spring hanger.
A practical feature of the ICW design is its preload spacer.
During the initial stages of ceiling installation, the preload arrangement temporarily keeps the spring assembly stable while the ceiling grid and gypsum board are being installed.
As the specified ceiling mass is added, the load compresses the spring into its designed operating range and activates the resilient isolation system.
This configuration assists contractors during installation while allowing the completed ceiling to achieve the intended spring deflection.
KINETICS® ICW can be incorporated into tested fire-rated floor-ceiling and roof-ceiling assemblies.
UL Design L581 covers a one-hour-rated assembly using various structural framing configurations, including dimensional wood joists, engineered wood members and open trusses.
Additional published UL assemblies associated with ICW applications include L521 and P522, depending on the floor, roof and structural framing arrangement.
Fire resistance must always be based on the complete tested assembly and the applicable approved project construction.
For official manufacturer details, drawings and specifications, refer to KINETICS® ICW technical information.
ICW is intended for applications where the ceiling isolation system is supported from joists, engineered wood members or compatible truss construction.
Where an isolated ceiling is suspended below a concrete deck or other structural deck, the KINETICS® ICC Ceiling Hanger provides a dedicated deck-suspended 1-inch spring isolation solution.
Kinetics Group also provides the KINETICS® WAVE Hanger and other engineered ceiling isolation products for project-specific acoustic requirements.
Selecting the correct hanger system should therefore be based on the supporting structure, ceiling load, available ceiling void, required acoustic performance and project specification.
Kinetics Group provides engineered acoustic, noise control and vibration isolation solutions from Dubai, UAE, supporting consultant-specified projects throughout the UAE and wider Middle East and MENA region.
KINETICS® ICW is suitable for projects where the acoustic design requires a high-performance isolated gypsum ceiling supported from compatible joist or truss construction.
Project teams can contact Kinetics Group for product selection, technical data, ceiling hanger layouts, submittal requirements and project-specific acoustic isolation requirements.
KINETICS® ICW is an acoustic spring ceiling hanger designed to resiliently support suspended gypsum board ceilings and reduce the transmission of airborne sound, impact noise and structure-borne vibration.
ICW uses coil springs designed for up to approximately 1 inch / 25 mm nominal rated deflection, depending on the selected spring and applied load.
ICW is designed primarily for attachment to dimensional wood joists, engineered wood members and open-web or parallel-chord trusses.
Yes. ICW resiliently separates the suspended ceiling from the supporting structure and can significantly improve impact-noise isolation when incorporated into a correctly designed floor-ceiling assembly.
Yes. The spring-isolated ceiling arrangement helps reduce airborne sound transmission between spaces, particularly when combined with the required gypsum board mass, cavity insulation and perimeter isolation.
ICW is available in ten spring capacities with rated loads from 12 lb to 210 lb. The appropriate model should be selected according to the calculated load at each suspension point.
Published ICW assemblies have achieved tested ratings ranging from STC 57–76 and IIC 52–89, depending on the complete construction. A specific tested assembly published by Kinetics achieved STC 76 and IIC 62. These figures relate to complete tested assemblies and not to the hanger by itself.
ICW is primarily designed for joist and truss construction. For deck-suspended applications such as concrete ceilings, the KINETICS® ICC Ceiling Hanger is the appropriate Kinetics ceiling isolation solution.
Yes. The system’s nominal 1-inch spring deflection and low-frequency isolation characteristics make it suitable for cinemas, recording studios, home theatres and other noise-sensitive environments when included within a properly engineered acoustic ceiling assembly.
Kinetics Group supplies and supports KINETICS® ICW acoustic ceiling isolation systems from Dubai, UAE. For project enquiries, specifications and technical requirements, contact Kinetics Group.
Specify KINETICS® ICW Acoustic Spring Ceiling Hangers for resiliently suspended gypsum ceiling systems requiring high-performance control of airborne sound, impact noise and low-frequency structure-borne vibration.
For technical product selection, spring loading, ceiling isolation requirements, consultant submittals or project enquiries in the UAE, GCC and MENA region, contact Kinetics Group.
KINETICS® ICW acoustic ceiling hangers can be used in noise-sensitive residential, commercial and specialist acoustic environments where resilient ceiling isolation is required.
Typical applications include:
The final hanger arrangement, spacing and spring capacities should be selected according to the ceiling weight, structural configuration and acoustic performance requirements of each project.
KINETICS® ICW provides a combination of high acoustic performance and practical installation features:
A practical feature of the ICW design is its preload spacer.
During the initial stages of ceiling installation, the preload arrangement temporarily keeps the spring assembly stable while the ceiling grid and gypsum board are being installed.
As the specified ceiling mass is added, the load compresses the spring into its designed operating range and activates the resilient isolation system.
This configuration assists contractors during installation while allowing the completed ceiling to achieve the intended spring deflection.