Kinetics NGD High-Deflection Neoprene Vibration Isolation Pads are ribbed elastomer-in-shear isolators engineered to reduce noise, shock and high-frequency vibration from HVAC, MEP, mechanical and industrial equipment. Available in 45 and 65 durometer configurations with maximum rated loading of 60 or 120 PSI and static deflection up to approximately 0.19″ (4.8 mm), NGD pads provide effective vibration control for projects across the UAE, GCC, Middle East and MENA.
Engineered for Performance.
Kinetics Model NGD Neoprene Vibration Isolation Pads are ribbed elastomer-in-shear isolators designed to reduce the transmission of noise, shock and high-frequency vibration generated by HVAC, MEP, mechanical, industrial and process equipment.
NGD pads are primarily used beneath machinery and mechanical equipment located on grade-supported structural slabs or other non-critical support locations where compact elastomeric vibration isolation with greater deflection than conventional thin neoprene pads is required.
The NGD configuration uses high-quality oil- and water-resistant elastomer together with ribbed isolation layers and steel shim reinforcement where required. Alternately higher and lower ribs place the elastomer in shear, allowing controlled deformation under equipment load while maintaining stable support and effective high-frequency vibration isolation.
Kinetics NGD is a high-deflection ribbed elastomer vibration isolation pad designed to reduce noise, shock and high-frequency vibration from HVAC, MEP, mechanical and industrial equipment. NGD pads are available in 45 and 65 durometer configurations with maximum rated loading of 60 or 120 PSI. Published NGD static deflection reaches approximately 0.19″ (4.8 mm), with load capacities up to 9,700 lbs. depending on model. Kinetics Group supports NGD vibration isolation solutions for projects across the UAE, GCC, Middle East and MENA.
The Kinetics NG family is designed to provide greater static deflection than the NP family.
For Model NGD, published maximum operating deflection is approximately:
NGD-45: 0.19″ / 4.8 mm
NGD-65: 0.17″ / 4.3 mm
This increased elastomeric deflection makes NGD particularly useful where consultants require greater pad-type isolation performance while retaining the simplicity and compact installation of a neoprene vibration isolation pad.
Kinetics NGD pads are available in two elastomer hardness ratings.
45 durometer: Designed for maximum rated loading up to 60 PSI (4.2 kg/cm²).
65 durometer: Designed for maximum rated loading up to 120 PSI (8.4 kg/cm²).
The elastomer is oil and water resistant and is engineered to operate within published strain limits for reliable long-term vibration isolation.
Typical ribbed neoprene pad applications are intended for high-frequency mechanical equipment with minimum operating speeds of approximately 3600 RPM.
Published NGD sizes include:
4″ × 4″ / 102 × 102 mm
6″ × 6″ / 152 × 152 mm
9″ × 9″ / 229 × 229 mm
The broader Kinetics NP/NG product range can also be supplied in full 18″ × 18″ (457 × 457 mm) sheets for field cutting or drilling where permitted by the approved project requirements.
Published NGD load capacities range from approximately 400 lbs. to 9,700 lbs. (181 to 4,400 kg) depending on pad size and durometer.
NGD-4-45: 400–950 lbs.; maximum deflection 0.19″ / 4.8 mm
NGD-4-65: 720–1,925 lbs.; maximum deflection 0.17″ / 4.3 mm
NGD-6-45: 900–2,150 lbs.; maximum deflection 0.19″ / 4.8 mm
NGD-6-65: 1,600–4,300 lbs.; maximum deflection 0.17″ / 4.3 mm
NGD-9-45: 2,000–4,850 lbs.; maximum deflection 0.19″ / 4.8 mm
NGD-9-65: 3,650–9,700 lbs.; maximum deflection 0.17″ / 4.3 mm
Final model selection must be based on actual equipment support-point loading, required operating static deflection, equipment speed and the approved vibration isolation schedule.
Kinetics NGD neoprene vibration isolation pads are suitable for high-frequency vibration isolation beneath appropriate:
Model: NGD
Product Type: High-deflection ribbed elastomer vibration isolation pad
Isolation Principle: Elastomer-in-shear
Durometer Options: 45 or 65
Maximum Rated Loading: 60 or 120 PSI depending on durometer
NGD-45 Maximum Deflection: 0.19″ / 4.8 mm
NGD-65 Maximum Deflection: 0.17″ / 4.3 mm
Standard NGD Sizes: 4″, 6″ and 9″ square
Published NGD Capacity Range: 400–9,700 lbs. / 181–4,400 kg
Typical Minimum Equipment Speed: 3600 RPM
Material Properties: Oil- and water-resistant elastomer
Isolation Construction: Ribbed elastomer-in-shear with steel shim reinforcement where required
Manufacturer: Kinetics Noise Control, Inc.
Regional Support: UAE, GCC, Middle East and MENA
Kinetics Model NGD is a high-deflection ribbed elastomer vibration isolation product manufactured by Kinetics Noise Control, Inc. Kinetics Group provides regional product supply, technical selection and engineering coordination for HVAC, MEP, industrial and mechanical vibration-control projects across Dubai, Abu Dhabi, the wider UAE, GCC, Middle East and MENA region. Manufacturer performance data, dimensional information and technical documentation are available for consultant specifications, equipment vibration isolation schedules and contractor submittals.
Kinetics NGD Neoprene Vibration Isolation Pads provide:
For impact or shock-loading applications, Kinetics requires the normal allowable pad load capacity to be reduced by 50%. The applicable 65-durometer material rated for 120 PSI should be used in accordance with manufacturer guidance.
Final selection must remain within the applicable published loading and static-deflection limits.
Kinetics Group provides vibration isolation products and engineering support for consultants, MEP contractors, HVAC contractors, developers, industrial operators and facility engineering teams across Dubai, Abu Dhabi, the wider UAE, GCC, Middle East and MENA region.
Model NGD is particularly suited to projects requiring a compact neoprene vibration isolation solution with higher static deflection than conventional thin ribbed pads and manufacturer-published load, hardness and performance data for engineering selection.
The Kinetics manufacturer page confirms that NGD belongs to the NPS/NPD/NGS/NGD ribbed elastomer family used to control noise, shock and high-frequency vibration from grade-supported mechanical and industrial equipment.
For consultants and contractors comparing neoprene anti-vibration pads in the UAE, Kinetics NGD provides manufacturer-defined static deflection, durometer, pressure loading and model-specific capacity data for engineering selection. With published static deflection approaching 5 mm, NGD provides a higher-deflection pad-type isolation option for appropriate HVAC, MEP and industrial equipment where documented vibration-control performance is required.
Kinetics NGD pads are used to reduce noise, shock and high-frequency vibration from HVAC, MEP, mechanical and industrial equipment installed primarily on grade-supported structural slabs.
NGD-45 provides maximum published deflection of approximately 0.19″ (4.8 mm), while NGD-65 provides approximately 0.17″ (4.3 mm).
Kinetics NGD vibration isolation pads are available in 45 and 65 durometer elastomer configurations.
The 45-durometer material is designed for maximum rated loading up to 60 PSI (4.2 kg/cm²), while 65-durometer material is designed for up to 120 PSI (8.4 kg/cm²) at its rated deflection.
Published model-specific NGD sizes are 4″ × 4″, 6″ × 6″ and 9″ × 9″. The broader NP/NG range can also be supplied as 18″ square sheets for appropriate field-sizing requirements.
Published NGD capacities range from approximately 400 lbs. to 9,700 lbs. (181 to 4,400 kg) depending on pad size and durometer.
Yes. NGD pads are suitable for appropriate high-frequency HVAC equipment when selected according to actual support load, equipment speed and required static deflection. Kinetics Group has documented NGD neoprene pads beneath a Fresh Air Handling Unit installation.
Both are ribbed elastomer vibration isolation products, but NGD provides greater static deflection. NGD is rated at approximately 0.17–0.19″ (4.3–4.8 mm) depending on durometer, while NPD is approximately 0.08–0.09″ (2.0–2.3 mm).
Yes, for suitable applications, but Kinetics requires allowable pad capacity to be reduced by 50% under impact loading and specifies use of the applicable 65-durometer material.
Kinetics Group has also publicly documented NGD use beneath a fresh air handling unit, making FAHU/AHU terminology particularly relevant for this page.
The model-specific deflection and capacity values above are shown in Kinetics’ NGD performance table.
Install Kinetics NGD neoprene vibration isolation pads beneath the designated equipment support or bearing points shown on the approved equipment layout and vibration isolation schedule.
Ensure the supporting slab or structural surface is clean, level and capable of safely carrying the operating equipment load.
Select each NGD pad according to the actual load applied at the individual equipment support point, required static deflection and applicable pad durometer.
Distribute the equipment load uniformly across the isolation-pad bearing area. Do not unnecessarily oversize the pad area, as insufficient elastomer loading can prevent the pad from achieving its intended operating deflection.
Where laminated isolation-pad assemblies are required, neoprene layers shall be separated by and bonded to galvanized steel shim plates in accordance with the approved Kinetics configuration.
Ensure that the selected NGD model operates within its published load-capacity range and does not exceed its maximum rated static deflection.
For shock or impact applications, reduce allowable pad capacity by 50% and use the appropriate 65-durometer material in accordance with manufacturer requirements.
Final installation must comply with Kinetics technical documentation, the approved vibration isolation schedule, consultant specifications and project engineering requirements.